Publication
MRS Proceedings 1999
Conference paper

Micro-wear scan test on the carbon overcoats as thin as 6 nm or less

Abstract

Nitrogen-doped carbon (CNx) overcoats, ranging from 1 to 6nm in thickness, were deposited on magnetic recording disks by a DC-sputtering process. A critical load, based on the first occurrence of coating damage, was used as a semi-quantitative measure of the mechanical strength of these overcoats. It was found that the critical load decreased in a nearly linear manner with the CNx thickness from 6nm down to approx. 2nm regime. However, the 1nm thick CNx coating deviated from this trend with a significant decrease in critical load. High-resolution SEM was employed to find the critical loads as well as to reveal the details of the coating wear morphology and the CNx failure mechanism.

Date

Publication

MRS Proceedings 1999